Tectyl 891D
TECTYL® 891D CORROSION
PREVENTATIVE
MEETS MILITARY SPECIFICATION
MIL-PRF-16173E
If you need additional information on
Tectyl 891D, or it's Military Specification MIL-PRF-16173E, please give us a
call. Our dedicated team is eager to help.
TECTYL® 891D, Class I is a
solvent cutback, firm film, black asphaltic corrosion preventive compound.
TECTYL® 891D, Class I provides long-term protection for metallic surfaces
in indoor or outdoor exposure and during international shipments. TECTYL®
891D, Class I is approved under Military Specification MIL-PRF-16173E, which
supersedes MIL-P-116J.
| Tectyl 891D Laboratory Data |
Tectyl 846 Typical Properties |
| Tectyl 891D Flash, PMCC*, Minimum |
105°F |
| Tectyl Density, Weight/Gallon @ 77°F (25°C) |
7.3 ± 0.1 lbs./gallon |
| Tectyl 891D Specific Gravity @ 60°F (15.6°C) |
0.88 |
| Tectyl 891D Specific Gravity @ 60°F (15.6°C) |
2.5 mils |
| Tectyl 891D Recommended Dry Film Thickness
over Metal Profile |
340 sq. ft./gallon |
| Tectyl 891D Theoretical Coverage @
Recommended DFT |
8,303 sq. ft./gallon |
| Tectyl 891D Non-Volatile % by Weight |
60 ± 4 |
| Tectyl 891D Non-Volatile % by Volume |
53 ± 2 |
| Tectyl 891D Volatile Organic Content (VOC),
Maximum |
3.7 lbs./gallon |
| Tectyl 891D Approximate Dry to Touch Time @
77°F (25°C) |
2 hours |
| Tectyl 891D Cure Time |
24 hours |
| Tectyl 891D Resistance to Flow per
MIL-16173E |
Pass |
|
Tectyl 891D Accelerated Corrosion Tests: |
| 5% Salt Spray (Hours)
ASTM** B-117 @ Recommended DFT
(2x4x1/8 in. Polished Steel Panels) |
864 |
|
100% Relative Humidity (Hours)
ASTM D-1748 @ Recommended DFT
(2x4x1/8 in. Polished Steel Panels) |
960 |
| Weathering Hours (Federal Standard 141,
Method 6151 @ Recommended DFT) |
1200 |
Tectyl 891D Surface Preparation
The maximum performance of TECTYL
891D, Class I can be achieved only when
the metal surfaces to be protected are clean,
dry and free of rust, oil and mill scale.
Daubert Chemical Company recommends
that the metal substrate temperature be 50-
95°F (10-35°C) at the time of product
application.
Tectyl 891D Storage
Store TECTYL 891D, Class I at
temperatures between 50-95°F (10-35°C).
Mild agitation is recommended prior to use.
Tectyl 891D Application
TECTYL® 891D, Class I is formulated to be
used as supplied.Ensure uniform
consistency prior to use. Continued stirring
is generally not required. If the product
thickens due to cold storage or loss of
solvent during use, contact Daubert
Chemical Company.DO NOT THIN
TECTYL 891D, Class I. Incorrect thinning
will affect film build, dry time and product
performance. Daubert Chemical Company
recommends that the ambient and product
temperature be 50 - 95°F (10 - 35°C) at time
of application. TECTYL® 891D, Class I can
be spray or dip applied.
Tectyl 891D Caution
Adequate ventilation is required for cure and
to ensure against formation of a combustible
liquid.THE PARTIALLY CURED FILM
SHOULD NOT BE EXPOSED TO IGNITION
SOURCES SUCH AS FLARES, FLAMES,
SPARKS, EXCESSIVE HEAT, OR
TORCHES. Refer to the Material
Safety Data Sheet for additional handling
and first aid information.
Tectyl 891D Removal
TECTYL® 891D, Class I can be removed
with TECTYL® HPS solvent borne thinner,
vapor degreasing, hot alkaline wash, or low
pressure steam. TECTYL® 891D, Class I
can be removed from fabrics by normal dry
cleaning procedures. Avoid the use of
chlorinated or highly aromatic solvents
when removing from painted surfaces, as
these solvents may adversely affect paint.

|